Stratusphere™ SNMP Overview
Configuring Stratusphere to Send SNMP Traps
Stratusphere can be configured to send SNMP traps based on alerts that are generated. To configure SNMP within Stratusphere:
- Log in to the web UI for the Stratusphere Hub Administration module and navigate to the Alerting > Configuration tab.
- Under Enable alerts, select the Yes option.
- Scroll down to the Alert Notification section and configure SNMP.
Stratusphere does not have a custom defined Management Information Base (MIB) as of version 5.7.0. However, it does provide OIDs with additional information for the administrator. The following table lists the OIDs along with the values for each.
OID Name | OID | Description |
---|---|---|
Alert Date | "1.3.6.1.4.1.18956.1.1.2.1.2.1" | Date & Time of the alert |
Alert Category | "1.3.6.1.4.1.18956.1.1.2.1.2.2" | Possible values include Network, Machine, Storage, Host, Status, & Custom_Report. |
Alert Type | "1.3.6.1.4.1.18956.1.1.2.1.2.3" | Possible values include Machine, Storage, Host, Status, & Custom_Report. The Network Category has additional values such as Authorization_Failures, Service_Level_Failures, & Incomplete_Connections. |
Alert Message | "1.3.6.1.4.1.18956.1.1.2.1.2.4" | Simple and generic textual description of the alert |
Alert Report URL (if for report) | "1.3.6.1.4.1.18956.1.1.2.1.2.5" | URL to view the details of the alert within the UI. |